MANDÍK FDML Fire Damper
MANDÍK FDML Fire Damper
A specialized rectangular fire damper designed for wall integration with an exceptionally slim 150mm casing profile. Offering certified 90-minute fire and gas protection, it’s engineered for ventilation openings in fire-rated walls where minimal intrusion and reliable compartmentalization are critical.
Product Description
Key Features & Benefits
90-Minute Fire & Gas Barrier
EI 90 S certified to block fire and combustion gases between compartments.
Ultra-Slim Wall Profile
Unique 150mm internal wall casing width - minimizes structural intrusion.
Electric Actuation Only
Equipped with electric actuator (24V/230V) triggered by thermal fuse for positive closure.
Wall-Integrated Design
Specifically for installation within the thickness of fire-rated partition walls.
High-Cycle Reliability
Tested for 10,000 operational cycles with corrosion-resistant construction.
Full EN Certification
CE certified, EN 1366-2 tested, EN 13501-3 classified.
Technical Specifications
Size Range
Rectangular: 200×300 mm to 1000×1000 mm (W×H).
Fire Rating
Fire resistance: EI 90 S (90 minutes integrity, insulation & leakage control).
Standards
CE per EN 15650.
Tested per EN 1366-2.
Classified per EN 13501-3+A1.
Superior Leakage Control
Casing: Air Tightness Class ATC 4.
Blades: Class 3 (EN 1751).
Performance
Max Air Speed: 12 m/s.
Max Pressure on Blades: 1500 Pa.
Cycles: C (10,000).
Actuation System
Electrical actuator: 24V DC or 230V AC, initiated by thermal fuse.
Installation & Integration
Slim Wall Integration
Designed to fit within standard 150mm wall construction, minimizing space requirement.
Electrical Safety System
Connects to building fire alarm; thermal fuse triggers actuator for automatic closure.
Precision Installation
Requires careful alignment within wall cavity; professional installation essential.
Integrated Access
Accessible via wall grilles or inspection panels for testing and maintenance.
Partition Wall Specific
For use in fire-rated partition walls, not for floor/ceiling penetrations.
Use Cases
- Hotel Room Corridors
- Office Partition Walls
- Hospital Ward Partitions
- School & University Walls
- Retail Store Separations
Product brochure
Related Products
Related products
- Fire Dampers
MANDÍK FDMQ Fire Damper
- Fire Dampers
MANDÍK CFDM 250 Fire Damper
- Fire Dampers
MANDÍK FDMQ 180 Fire Damper
- Fire Dampers
MANDÍK MCS-P Electronic Control System
- Fire Dampers
MANDÍK MCS-B Electronic Control System
- Fire Dampers
MANDÍK DM-S Fire Damper
- Fire Dampers
MANDÍK FDMR Fire Damper
- Fire Dampers
MANDÍK FDMS Fire Damper
- Fire Dampers
MANDÍK FDMQ 120 Fire Damper
- Fire Dampers
MANDÍK FDMR 60 Fire Damper