MANDÍK FDMQ 180 Fire Damper
MANDÍK FDMQ 180 Fire Damper
A premium heavy-duty rectangular fire damper offering maximum 180-minute certified protection for the largest HVAC ducts. Engineered for critical applications in sizeable rectangular openings from 200x200mm to 1500x800mm, it delivers ultimate fire and smoke compartmentalization for high-risk and high-value facilities.
Product Description
Key Features & Benefits
Maximum 180-Minute Barrier
Top-tier EI 180 S certification for 3-hour fire & smoke protection in large ducts.
Dual Activation Methods
Mechanical fusible link or electrical actuator for integration with safety systems.
For Largest Rectangular Ducts
Designed for very large ducts from 200×200 mm to 1500×800 mm.
Critical Infrastructure Grade
Built for the most demanding applications in industrial plants and major facilities.
Exceptional Durability
Tested for 10,000 operating cycles with corrosion-resistant construction.
Full EN Certification
Certified per EN 15650, tested to EN 1366-2, classified per EN 13501-3.
Technical Specifications
Size Range
Large rectangular dimensions: 200×200 mm to 1500×800 mm (H×W).
Fire Rating
Maximum fire resistance: EI 180 S (180 minutes integrity, insulation & leakage control).
Standards
Certified per EN 15650.
Tested per EN 1366-2.
Classified per EN 13501-3+A1.
Leakage Class
External Casing: Leakage Class A (TC 3).
Internal (Closed): Leakage Class 3 (EN 1751).
Performance
Max Air Speed: 12 m/s.
Pressure Diff: Up to 1200 Pa.
Cycles: Class C (10,000).
Actuators
Mechanical: Fusible link (72°C).
Electrical: 24V/230V motor for automatic control.
Installation & Integration
Heavy Structural Installation
For large duct penetrations; requires professional engineering and structural support.
Advanced System Integration
Electric models connect to fire alarm and building management systems for automated response.
Fail-Safe Mechanical Option
Fusible link ensures automatic closure without external power or control signals.
Service & Testing Access
Designed with inspection hatches for routine testing, maintenance, and post-activation reset.
Engineered Support System
May require custom support framing due to the large dimensions and weight of the unit.
Use Cases
- High-Risk Industrial Plants
- Skyscrapers & Landmarks
- Underground Transport Systems
- Major Trauma & Research Hospitals
- Government & Military Facilities
Product brochure
Related Products
Related products
- Fire Dampers
MANDÍK FDMR 180 Fire Damper
- Fire Dampers
MANDÍK CFDM / CFDM-V Fire Damper
- Fire Dampers
MANDÍK MCS-P Electronic Control System
- Fire Dampers
MANDÍK FDMQ 120 Fire Damper
- Fire Dampers
MANDÍK FDMQ Fire Damper
- Fire Dampers
MANDÍK FDMR Fire Damper
- Fire Dampers
MANDÍK FDMA Fire Damper
- Fire Dampers
MANDÍK FDMB Fire Damper
- Fire Dampers
MANDÍK DM-S Fire Damper
- Fire Dampers
MANDÍK CFDM 250 Fire Damper