MANDÍK MCS-P Electronic Control System

MANDÍK MCS-P Electronic Control System

An innovative fire damper control system using Powerline Communication (PLC) technology to monitor and control up to 64 dampers via existing 230V AC power cables, eliminating separate data wiring. It features a central control unit with automatic module detection, supports flexible wiring topologies, and integrates seamlessly with building management systems using open protocols.

Product Description

Key Features & Benefits

  • No Extra Data Cables

    Uses existing 230V AC power lines for communication, drastically reducing installation cost and complexity.

  • Free Wiring Topology

    Supports star, line, bus, or tree topologies for maximum installation flexibility.

  • Centralized Intelligent Control

    Central unit with touchscreen provides overview, control, and diagnostics for all 64 dampers.

  • Automatic Module Detection

    Master unit automatically detects all slave modules (BKN230-24-PL) via unique MAC addresses.

  • Open Protocol Integration

    Supports Modbus RTU/TCP and BACnet MS/TP/IP for easy BMS/BAS integration.

  • Remote & Cloud Capabilities

    Optional TCP/IP communication for monitoring on external PCs or touchscreen panels.

Technical Specifications

System Capacity

Max Dampers: 64. Max Modules: 64 BKN230-24-PL communication modules.

Power & Communication

Technology: Powerline Communication (PLC) over 230V AC. Actuator Support: 24V AC/DC.

Range & Topology

Max Distance: 1200m (Master to farthest module). Topology: Star, Line, Bus, Tree.

Module Features (BKN230-24-PL)

Per module: 1 damper, 1 smoke detector input. Measures end-switch time & power consumption.

Central Unit Features

Touchscreen, integrated PLC filter, relay outputs (for duct venting), optically isolated inputs, USB port.

Communication Protocols

Field: Powerline. Integration: Modbus RTU/TCP, BACnet MS/TP/IP.

Installation & Integration

Plug-and-Play over Powerlines

Connect modules to 230V AC power; communication is carried over the same wires.

Flexible Topology Installation

Wire in any convenient pattern (star, bus, etc.) up to 1200m total distance.

Automatic Commissioning

System auto-discovers all modules; no manual addressing or complex setup required.

Network Integration

Connect central unit to building LAN (TCP/IP) for remote access, monitoring, and event logging.

On-Site Diagnostics

Use USB interface on central unit for local configuration, diagnostics, and data export (PDF/CSV).

Use Cases

Product brochure
Scroll to Top

عيدكم مبارك

شركة دار الموارد للتجارة
بيئة آمنة وهواء نقي
كل عام وأنتم بخير ⭐⭐ كل عام وأنتم بخير ⭐⭐ كل عام وأنتم بخير ... 2026-1447